- Secure, reliable long-term operation – robust and completely welded sensor
- Energy-saving flow measurement – no pressure loss due to cross-section constriction
- Maintenance-free – no moving parts
- Fast commissioning – application-specific Quick Setups
- Safe operation – display provides easy readable process information
- Fully industry compliant – IEC/EN/NAMUR
-
The sensor with degree of protection IP68 (Type 6P enclosure) and a modular electronic concept Promag W is the specialized sensor for all applications in the water industry. Combined with the proven Promag 50 transmitter with push buttons, Promag 50W offers highly accurate measurement of liquids for a wide range of standard applications. Promag 50W is available in a compact or remote version. Benefits:
-
Vortex flow measuring system Reliable flow measurement of gas, steam and liquids Models:
- Prowirl 72F / 72W
- Prowirl 73F / 73W
- Fluid temperature range from –200 to +400 °C
- Pressure ratings up to PN 250/Class 1500
- Sensor with integrated (optional) diameter reduction by one line size (R Style) or two line sizes (S Style)
- Dualsens version (optional) for redundant measurements with two sensors and electronics
- ATEX, FM, CSA, TIIS, NEPSI, IEC
- HART, PROFIBUS PA, FOUNDATION Fieldbus
- Pressure Equipment Directive, SIL 2
-
A high level of performance, together with a wide operating temperature range up to 400°C /752°F, makes the OPTIMASS 6000 the ideal choice for mass flow measurement in a wide variety of applications.d Designed to meet the requirements of general purpose liquid and gas applications, the extended low temperature range of -200°C / -328°F also makes the 6000 suitable for Liquid Natural Gas (LNG) and cryogenic applications.d Combined with the power of the MFC 400, the OPTIMASS 6000 will provide accurate measurement of volume, mass, density and concentration.dFeatures:
- Innovative twin V-tube design
- Temperature range -200°C to +400°C
- Optional insulation / heating jacket
- Compact envelope
- Optimised flow divider for minimum pressure loss
- Modular electronics concept: electronics and sensor are easy to replace
- Self draining when mounted vertically
- Stability with entrained gas, even with gas concentrations 0...100%
-
The Krohne OPTIMASS 7000 coriolis mass flow meter is the optimum meter for demanding mass flow and density measurement applications of fluids, gases and solids. Featuring a single straight titanium measuring tube, the OPTIMASS 7000 is ideal for use in applications involving highly corrosive fluids, custody transfer, non-homogenous mixtures, and slurries.d
Features:
- Outer cylinder typical burst pressure greater than 100 barg / 1450 psig, with optional PED approved secondary pressure containment available
- Easily drained and easy to clean
- Resistant to installation and process effects
- Excellent zero stability
- Low energy consumption, means lower operating costs
- Rapid signal processing, even with product / temperature changes
- Modular electronics with data redundancy - "plug & play" replacement of electronics
-
The H 250 flowmeter for measurement of the volumetric or mass flow rate of liquids, gases and steam is an all-metal flowmeter that operates on the float measuring principle. The flow-dependent vertical position of the float in the measuring tube is transmitted by a magnetic coupling system to the scale in the indicator part. The flowmeter is installed in a vertical pipe run, with flow from bottom to top. Owing to its rugged design, the H 250 variable-area flowmeter is particularly suitable for difficult applications and environmental conditions.D In the M9 indicator, the vertical position of the float is transmitted to the pointer/ magnet system, and the flow value indicated directly on the scale.D
-
The DK 37 variable area flowmeters can either be equipped with a mechanical or electronic indicator and are suitable for measuring gases and liquids. They are sturdy, versatile all-metal measuring devices. All devices are fitted with a metering valve to accurately set the flow value.Its suitability for measuring the flow of gases in accordance with the DVGW G260 process sheet has been certified by the DVGW testing station at the Gas-Fired Thermal Energy Institute in Essen/Germany.d
-
The new standard solution for the process industry. The H250/M40 flowmeters are setting a new standard in variable area flowmeter technology. They combine tried and tested flow measurement with latest communication capabilities like Foundation Fieldbus.
The functionality of the devices is modular extendable. The innovative construction allows a free choice of intrinsically safe or flameproof design.
The sturdy all-metal design, availabale in different materials, ensures high resistance to pressure, temperature and media and stands up to extreme application and environmental conditions. The new H250/M40 is the new standard solution for the process industry when costs and reliability are a factor.
-
The OPTIMASS 1000 is the cost ef fective solution for accurate measurement for a variety of applications. The OPTIMASS 1000 reliably measures massflow, density, volume, temperature volume concentration or solid contentFeatures:
- Suitable for all standard applications up to 130°C
- Hygienic connections make it ideal for food / beverage applications
- Innovative twin measuring tubes
- Easily drained and easy to clean
- Resistant to installation and process effects
- Long working life.
- Optimized flow divider for minimum pressure loss.
- High levels of accuracy means an excellent price / performance ratio.
- Modular electronics with data redundancy - "plug & play" replacement of electronics
Industries:- Water & wastewater
- Chemical
- Food & beverage
- Paper & pulp
- Petrochemical industry
- Pharmaceutical industry
-
The Krohne OPTIMASS 2000 coriolis mass flow meter is a large diameter instrument developed to meet the demanding custody transfer requirements of the oil and gas industry. The high performance of the OPTIMASS 2000 also makes it a suitable flow meter for the bulk measurement of petroleum and oil as well as products like syrup, molasses and raw chemicals.d
Features:
High accuracy for custody transfer Innovative twin measuring tube design with optimised flow divider for minimum pressure loss Flow rates up to 2,300,000 kg/h /85,000 lbs/min. Standard flanges with ratings up to 1,500 lbs / PN160 Modular integrated electronics concept: electronics and sensor are easy to replace Optional heating jacket Large tube size for bulk measurement Best in class for zero stability Easily drained and easy to clean